9. STL model import (planning with CT scan)
9. STL model import (planning with CT scan)
Existing STL models are imported into Blue Sky Plan® by selecting “File > Import STL Model”. After the model has loaded, the “Model Alignment” panel (2) opens in addition to the aligned model in the 3D window (1). Using this panel the model can be positioned in the desired location.
If the model is already aligned with respect to the data, the “Direct alignment” should correspond to the correct position of the model. For STL models created with different software than Blue Sky Plan®, use the “DICOM coordinates” alignment.

It is essential that the dental curve is set correctly in order for the automatic alignment of the model to the teeth to work correctly. After setting it in the “Alignment” section (2) of the “Model Alignment” panel, select "Auto" in the "Orientation" section (4). Then select the corresponding jawbone and perform alignment with the "Align" button (5).
Because automatic alignment is usually not precise enough, Blue Sky Plan® also makes it possible to perform the alignment by entering a pair of points corresponding to each other. If you select “Points” (3) and click “Align” (5) in the "Alignment" section, a dialog appears for entering points manually. The surface model displayed in the left-hand window of the dialog is created on the basis of the settings of the currently selected density surface. You can also significantly influence the time it takes to create the model and the visibility of appropriate reference points by setting the thresholds of the density surface appropriately.

Points can be added by clicking on the button with the eyedropper

or by pressing the Shift key. If “Refine using ICP” is activated, the program attempts to perform an additional automatic alignment after the alignment based on the points entered.
It is also possible to align the model manually in the 3D window using the dragger (7) that appears when you press the “Adjust Model Position Manually” button (6). Clicking this same button closes the manual alignment mode, and the dragger disappears.

When aligning manually (6), it is possible to define a fixed point (a so-called pivot) around which the model rotates. In 2D views, the pivot is represented by a cross (8). By dragging the cross, it is possible to move the model in the plane of view. The model can be rotated using the blue circle (9). Hold SHIFT and click the mouse button to position the pivot at a different position in 2D views. In the 3D window, the pivot can be repositioned using the small dragger arrows (7).
Back to Content Page
Previous Page 8.2. Gutta percha markers do not coincide
Next Page 10. Planning without CT scan